When pressure sensors come into contact with hydrogen, this often results in difficulties. Unfortunately, I very often notice in my job our customers are not aware of this ahead of use. Because of this , they often usually do not even tell us that their medium contains hydrogen. Willpower find out when we receive a complaint. But why do we get yourself a complaint? Why is especially Dazzling to pressure sensors?
A simple rule is that a lot of metals become brittle when exposed to hydrogen. Hydrogen atoms that diffuse in to the metal grid change the effectiveness of the material. In the worst case, this results in cracks in the material. Or even to put it simply, the pressure sensor starts leaking or is totally destroyed. In the case of pressure sensors, in particular thin membranes necessary for measuring pressure play a decisive role. Atomic hydrogen will not only penetrate the metal, but also pass through it by diffusion.
It has several effects: When piezoresistive measuring principles are employed, it becomes critical if hydrogen reacts with the inner transmission medium or accumulates there. This initially only falsifies the measurement results, but can down the road also lead to complete destruction of the sensor in individual cases. The addition of hydrogen also changes the instrumentation characteristics of the resistance structures of the measurement bridge of thin-film sensors. Despite being reversible, this process leads to a detuning of the bridge at the very least temporarily, resulting in a falsification of the measurement signal.
However, the consequences described above occur in various materials differently. This means that the effects of hydrogen can be lowered substantially by selecting suitable materials.
Note
Further information on our pressure sensors and on the subject of hydrogen can be found on the WIKA website. If you are using hydrogen as the medium, your contact will gladly recommend an optimum solution for your application.